Help using the Scout Keratron

   available on Crystal PM 3.0.0+

   this should work for the Scout Keratron

 

Setting Crystal PM to work with Scout Keratron

1)  Create Folder c:\keratron\system\db

2)  Download File db.ini into c:\keratron\system\db folder

3)  Download File crystal.ico into c:\keratron\system\db folder

4)  Add Button to Medical Records with Command “EyeQuip – View”

5)  Add Button to Medical Records with Command “EyeQuip – Capture”

6)  Add Machine Import -> Scout

 

 

 

Assigning a Field from the Machines Data file.

1) Edit the Medical Records

2) Click on the field which will receive the input values

3) Change the description to SCOUT:ID (ex -> [SCOUT:2] for Time From Export)

 

Fields available to be assigned from Data File

ID          Data                                Example_________________________________

1        File Location                          C:\keratron\system\db\scout2db.ini

2        Time                                   03:30 PM

3        OD Test number                         12

4        OD Image number                        1

5        OD Test Date                           05/16/2010

6        OD Test time                           15:16:25

7        OD SimK flat mm                        8.06379462523064

8        OD SimK flat ax                        29.53125

9        OD SimK steep mm                       7.87207171648669

10       OD SimK steep ax                       119.5313

11       OD Pupil diameter mm                   3.010307

12       OD Pupil position X mm                 6.379757

13       OD Pupil position Y mm                 5.565597

14       OD SimK Zone                           8

15       OD SimK flat e                         0.5930589

16       OD SimK flat Q                         -0.3517188

17       OD SimK flat Ro                        8.008204

18       OD SimK steep e                        0.5318012

19       OD SimK steep Q                        -0.2828125

20       OD SimK steep Ro                       7.828516

21       OD CLMI_Screening_Ma                   0.33

22       OD CLMI_Screening_PPK                  0.2

23       OD CLMI_Screening_Color                G

24       OS Test number                         12

25       OS Image number                        1

26       OS Test Date                           05/16/2010

27       OS Test time                           15:16:25

28       OS SimK flat mm                        8.06379462523064

29       OS SimK flat ax                        29.53125

30       OS SimK steep mm                       7.87207171648669

31       OS SimK steep ax                       119.5313

32       OS Pupil diameter mm                   3.010307

33       OS Pupil position X mm                 6.379757

34       OS Pupil position Y mm                 5.565597

35       OS SimK Zone                           8

36       OS SimK flat e                         0.5930589

37       OS SimK flat Q                         -0.3517188

38       OS SimK flat Ro                        8.008204

39       OS SimK steep e                        0.5318012

40       OS SimK steep Q                        -0.2828125

41       OS SimK steep Ro                       7.828516

42       OS CLMI_Screening_Ma                   0.33

43       OS CLMI_Screening_PPK                  0.2

1        OS CLMI_Screening_Color                G